HbA1c FIA Rapid Test

HbA1c FIA Rapid Test

Method: Microfluidic Fluorescent Immunoassay
Test: LYOFIA® HbA1c
Format: Cassette
Reaction Time: 10mins
Linearity: 3.8%~14%
Reference Interval: 4.0%~6.0%

Product Introduction

Intended use

 

This HbA1c FIA Rapid Test is developed for the in vitro qualitative detection of HbA1c in human serum, plasma, and performed on self-developed LYOFIA® platform by VAUCRE Biotech.

It is for in vitro diagnostic use only, not for self-testing of untrained individuals.

 

Summary

 

Diabetes is a group of syndromes caused by a series of metabolic disorders of protein, fat, water, and electrolytes due to absolute or relative insufficient secretion of insulin and reduced sensitivity of target tissue cells to insulin, among which hyperglycemia is the main sign.

The main clinical manifestations of diabetes are polydipsia, polyuria, polyphagia and weight loss ("three more and one less"), as well as high blood sugar and glucose in the urine (normal urine should not contain glucose). If diabetes is not effectively treated, it can cause damage to multiple systems of the body, leading to chronic progressive disease, functional decline and failure of the eyes, kidneys, nerves, heart, blood vessels and other tissues and organs. Acute and severe metabolic disorders, such as diabetic ketoacidosis and hyperosmolar hyperglycemic syndrome, may occur when the condition is severe or under stress.

 

product-562-483

Key global findings

 

There are over 3 in 4 adults with diabetes live in low- and middle-income countries.

 

◉ More than 537 million,10.5% of the adult population (20-79 years) has diabetes, with almost half unaware that they are living with the condition.

◉ Pulse iconDiabetes is responsible for 6.7 million deaths in 2021 - 1 every 5 seconds.

◉ By 2045, IDF projections show that 1 in 8 adults, approximately 783 million, will be living with diabetes, an increase of 46%.

 

 

Why Test HbA1c?

 

 

Glycosylated hemoglobin (HbA1c) is the product of the non-enzymatic reaction between glucose and hemoglobin. The reaction is irreversible. The HbA1c level is stable and can reflect the average blood sugar level in the 2 months before blood collection. It is the most valuable indicator to judge the status of blood sugar control.

 

product-766-428

 

Advantage

 

 

A better A1C test means better diabetes care.

 

VACURE Biotech provides EXCELLENT HbA1c Test performance for clinical reference.

 

· Accurate 

 

 product-228-221    

The CV. of Repeatability and within-laboratory imprecision is no more than 10%,the CV. of inter-lot imprecision is no more than 15%.

 

· Fast   

 

 product-265-149       

The HbA1c FIA Rapid Test detects the amount of HbA1c in whole blood sample within just 10 minutes.

 

· Easy to use

product-225-225

Without the use of cumbersome laboratory equipment,but just requiring minimally trained laboratory personnel.

 

 