Package size
100 Tests, 50 Tests, 25 Tests, 10 Tests, 5 Tests, 100 Tests (N-QC), 50 Tests (N-QC), 25 Tests (N-QC), 10 Tests (N-QC), 5 Tests (N-QC).
Intended use
This device is intended to be used for the in vitro qualitative detection of 5 items in human alveolar lavage fluid, sputum, nasal swab, nasopharyngeal swab or oropharyngeal swab related to the respiratory infection, including antigens of Influenza A (Flu A), Influenza B (Flu B), Respiratory syncytial virus (RSV), human Adenovirus (hAdV) and SARS-CoV-2. And it is for professional use only, not for self-testing of untrained individuals, nor for near-patient testing.
Summary
Influenza and lower respiratory tract infections are significant causes of worldwide morbidity and mortality. Influenza virus is globally estimated to cause over one billion infections and 500,000 deaths each year, with the highest burdens in infants and young children, the elderly, and those with underlying medical conditions such as chronic lung disease. Influenza types A and B can cause human epidemics; however, in the case of most human pandemics, novel strain emergence and a greater overall disease burden is attributed to type A.
Respiratory syncytial virus is a leading cause of lower respiratory tract infections and hospitalizations in infants and children, with most children having had an RSV infection by two years of age.
In children five years of age or younger, there are over 3 million hospitalizations and over 100,000 globally estimated deaths from lower respiratory RSV infections. More recently, due in part to diagnostic improvements, RSV has also been associated with a substantial disease and health economic burden in older adults.
Adenoviruses have a linear double stranded ~ 40 kb DNA genome, containing 30-40 genes. The virus affects membranes of the respiratory tract, eyes, intestines, and urinary tract. Symptoms of respiratory illness range from the common cold to pneumonia and bronchitis. Adenoviruses account for about 10% of acute respiratory infections in children and are a frequent cause of diarrhea. The disease is usually mild and requires at most a symptomatic treatment. Immune-compromised patients are vulnerable to severe complications of Adenovirus infections. Transmission is airborne or fecal route. The 51 serotypes of human adenovirus (hAdV) are divided into six groups named from A to F. Respiratory diseases are mainly due to virus from groups B and C, conjunctivitis to groups C and D, while the causative virus for gastroenteritis is probably limited to group F viruses (types 40 and 41 only). Routine diagnosis is accomplished by antigen testing, serology, or PCR.
The novel coronavirus belongs to the βgenus. SARS-CoV-2 is an acute respiratory infectious disease. People are generally susceptible. Currently, the patients infected by the novel coronavirus are the main source of infection; asymptomatic infected people can also be an infectious source. Based on the current epidemiological investigation, the incubation period is 1 to 14 days, mostly 3 to 7 days. The main manifestations include fever, fatigue and dry cough. Nasal congestion, runny nose, sore throat, myalgia, and diarrhea are found in a few cases.
The current clinical methods include fluorescence immunochromatography, chemiluminescence and so on.
PRODUCT PARAMETER
TEST PARAMETER | |||
Method | Microfluidic Fluorescent Immunoassay | Test | DISKFLU® RVAg-5 |
Format | DISC | Reaction Time | 15min |
Detection | FLU A/ FLU B/ RSV/ADE / SARs2 | Interpretation | Negative ≤ 1 |
Sample | Swab / BALF | Certificate | CE/NMPA |
ORDERING | |||||
Cat. No. | DMIN5R10 | Applicable analyzer | DISKFLU | Kit Size | 10T |
Cat. No. | DAIN5R10 | Applicable analyzer | DISKFLU 1000 (Full-Automatic) | Kit Size | 10T |
APPLICATION SCENARIOS

Hospitals

Laboratory

Clinics

Ambulance

Cardiology

Pediatrics

Emergency

CSC
FAQ
Q: What is our product testing time?
A: There are 5-15 minutes, CRP is 5 minutes, and most others are 10 minutes.
Q: How many items can DISKFLU detect at one time?
A: Currently, 9 items can be detected at one time.
Placed under the two instrument detail pages of DISKFLU.
Q: How long is the usual delivery time?
A: The regular delivery time is about 2 weeks. If you need to do new packaging (OEM), the delivery time for the first order is 25-30 days, and the second order starts and the regular delivery time is the same.