Package size
100 Tests, 50 Tests, 25 Tests, 10 Tests, 5 Tests, 100 Tests (N-QC), 50 Tests (N-QC), 25 Tests (N-QC), 10 Tests (N-QC), 5 Tests (N-QC).
Intended use
This device is intended to be used for the in vitro quantitative determination of B-type Natriuretic Protein (BNP) in human whole blood, serum or plasma. And it is for professional use only, not for self-testing of untrained individuals, nor for near-patient testing.
Summary
The 134-amino acid pre-proBNP produced after stimulation of cardiomyocytes is further converted into a 108-amino acid proBNP. The latter is cleaved under the action of endoproteinase into N-terminal proBNP (NT-proBNP) containing 76 amino acids, which is biologically inactive, and B-type natriuretic peptide (BNP) containing 32 amino acids, which is active. Since BNP is mainly synthesized by left ventricular cardiomyocytes and then secreted into the blood, it can be used as an effective marker of heart failure and can independently predict the increased ventricular pressure. It is of great value in the auxiliary diagnosis, treatment evaluation and monitoring for congestive heart failure, dyspnea complications caused by congestive heart failure, the essential hypertension, left ventricular dysfunction and other cardiovascular-related diseases.
The current clinical methods for detecting BNP include double antibody sandwich immunoluminescence assay, colloidal gold immunochromatography and so on.
hemiluminescence method, immunochromatography method, and etc.
PRODUCT PARAMETER
|
TEST INFORMATION |
|||
|
Method |
Microfluidic Fluorescent Immunoassay |
Test |
LYOFIA® BNP |
|
Format |
Cassette |
Reaction Time |
10min |
|
Linearity |
5~5000pg/mL |
Reference Interval |
<100pg/mL |
|
Sample |
S / P |
Certificate |
CE / NMPA |
|
ORDERING |
|||||
|
Cat. No. |
LMCMBN25 |
Applicable analyzer |
LYOFIA-I, LYOFIA 8, |
Kit Size |
25T |
|
Cat. No. |
LACMBN25 |
Applicable analyzer |
LYOFIA 100 (Full-Automatic) |
Kit Size |
25T |
APPLICATION SCENARIOS
Hospitals
Laboratory
Clinics
Ambulance
Cardiology

Pediatrics
Emergency
CSC
FAQ
Q: Is it possible to OEM?
A: Yes. Clients need to authorize brands and provide design solutions.
Q: How long is the usual delivery time?
A: The regular delivery time is about 2 weeks. If you need to do new packaging (OEM), the delivery time for the first order is 25-30 days, and the second order starts and the regular delivery time is the same.
Hot Tags: b-type natriuretic protein (bnp) kit, China, suppliers, manufacturers, factory, pricelist, quotation












